Support / Technical Data
Tensile Membrane Structure
Technical Data & Engineering Specifications
Full material specifications, steel grades, structural performance data, and engineering capabilities for every Jutent project.
Membrane Material Specifications
Jutent supplies tensile membrane structures using two primary high-performance fabric types: PVDF (Polyvinylidene Fluoride) and PTFE (Polytetrafluoroethylene). For applications requiring partial shading with airflow, mesh fabric is also available. All membrane materials are available in a wide range of standard and custom colours — white is the most widely specified, but custom colour matching is available upon request.
Full material data sheets (MDS) for each membrane grade are available for download on our Documentation page →
ПВДФ мембрана
The standard choice for commercial and institutional projects. Strong UV resistance, self-cleaning surface, and cost-effective across all grades.
| Параметр | 950 g/m² | 1050 g/m² | 1150 g/m² | 1300 g/m² | 1400 g/m² |
|---|---|---|---|---|---|
| Tensile Strength (Warp) | ≥ 4,500 N/5cm | ≥ 5,500 N/5cm | ≥ 6,000 N/5cm | ≥ 7,000 N/5cm | ≥ 8,000 N/5cm |
| Tensile Strength (Fill) | ≥ 4,000 N/5cm | ≥ 5,000 N/5cm | ≥ 5,500 N/5cm | ≥ 6,500 N/5cm | ≥ 7,500 N/5cm |
| UV Blocking Rate | 99% | 99% | 99% | 99% | 99% |
| Light Transmittance | ~20% | ~20% | ~18% | ~15% | ~12% |
| Самоочищение | Yes | Yes | Yes | Yes | Yes |
| Membrane Warranty | 10 лет | 10 лет | 10 лет | 10 лет | 10 лет |
| Typical Use | Small / cost-sensitive | Standard commercial | Medium-span | Large-span / high-wind | Extreme / coastal / typhoon |
ПТФЭ мембрана
Specified for permanent landmark structures where longevity, fire compliance, and minimal maintenance are priorities. Class A non-combustible, 15-year warranty.
| Параметр | 950 g/m² | 1050 g/m² | 1150 g/m² | 1250 g/m² | 1350 g/m² |
|---|---|---|---|---|---|
| Tensile Strength (Warp) | ≥ 4,800 N/5cm | ≥ 5,800 N/5cm | ≥ 6,500 N/5cm | ≥ 7,500 N/5cm | ≥ 8,500 N/5cm |
| Tensile Strength (Fill) | ≥ 4,200 N/5cm | ≥ 5,200 N/5cm | ≥ 6,000 N/5cm | ≥ 7,000 N/5cm | ≥ 8,000 N/5cm |
| UV Blocking Rate | 99% | 99% | 99% | 99% | 99% |
| Light Transmittance | ~15% | ~13% | ~12% | ~10% | ~8% |
| Класс пожарной безопасности | Class A | Class A | Class A | Class A | Class A |
| Самоочищение | Отлично | Отлично | Отлично | Отлично | Отлично |
| Membrane Warranty | 15 лет | 15 лет | 15 лет | 15 лет | 15 лет |
| Typical Use | Lightweight permanent | Standard permanent | Medium-span permanent | Large-span landmark | Stadium / airport / civic |
For applications requiring partial shading with natural ventilation — open-air sports courts, playgrounds, agricultural structures. Blocks 50–90% solar radiation depending on shade factor. Contact us to discuss suitability.
Jutent works with internationally recognised suppliers including Duken, Ferrari, Sattler, Hightex, and Castillo. Brand selection is confirmed at the engineering stage based on project requirements.
Steel Structure Specifications
All steel components are fabricated to international structural standards. Jutent primarily uses two steel grades, each mapped to the equivalent international standard for the benefit of overseas contractors and engineers.
| Jutent Grade | US Equivalent | EU Equivalent | Yield Strength | Tensile Strength | Typical Use |
|---|---|---|---|---|---|
| Q355B | ASTM A572 Gr.50 | EN S355JR | ≥ 355 MPa | 470–630 MPa | Main columns, beams, primary frames |
| Q235B | ASTM A36 | EN S235JR | ≥ 235 MPa | 370–500 MPa | Secondary members, purlins, bracing |
Surface Treatment & Anti-Corrosion
Structures are designed with bolted connections as the primary assembly method — no specialised welding equipment required on site. Column base connections allow on-site welding to accommodate foundation tolerances.
The structural steel frame carries a 2-year warranty covering fabrication quality and structural integrity under normal use conditions.
Structural Performance Data
Structural Calculation Standards
Our structural calculations are prepared in accordance with Chinese national standards (GB 50009 / GB 50017). For projects requiring international standards such as ASCE 7 (US) or AS/NZS 1170 (Australia / New Zealand), we can accommodate this upon request.
Complete calculation documentation is provided with every project. If your local authority requires review by a locally licensed engineer, we supply the full dataset — load inputs, section properties, and analysis outputs — to support that process.
Engineering & Design Capabilities
Every Jutent project is backed by a full engineering workflow — from initial concept modelling through to fabrication drawings and on-site installation guidance.
Deliverables Included with Every Project
Finite element analysis of a tensile membrane canopy structure — stress distribution visualisation
Quality Assurance
Quality control is built into every stage of our production process — from raw material inspection through to pre-shipment checks. Our fabrication workflow covers incoming material verification, in-process weld inspection, surface treatment thickness measurement, and final dimensional checks before packing.
Coating thickness inspection on fabricated steel components prior to shipment
Часто задаваемые вопросы
What membrane weight do you recommend for a project in Southeast Asia?
For standard commercial projects in Southeast Asia, we typically specify 1050 g/m² PVDF as the baseline. For coastal locations or areas with typhoon exposure, we upgrade to 1300 g/m² and increase the steel frame section sizes accordingly. All recommendations are confirmed after reviewing the project’s wind zone classification.
Can you provide a structural calculation report for permit applications?
Yes. We produce structural calculation reports based on Chinese national standards (GB 50009 / GB 50017). If your project requires ASCE 7, AS/NZS 1170, or another international standard, we can accommodate this upon request. If your local authority requires a locally licensed engineer to review or co-sign the report, we provide the complete calculation dataset to support that process.
В чем разница между мембраной ПВДФ и ПТФЭ?
PVDF membrane uses a PVC base fabric coated with polyvinylidene fluoride. It offers excellent UV resistance, a 10-year warranty, and is the most cost-effective choice for the majority of commercial projects. PTFE membrane uses a glass-fibre base with a PTFE coating — non-combustible (Class A fire rating), 15-year warranty, specified for permanent landmark structures.
Can I specify a custom colour for the membrane?
Yes. Membrane is available in a wide range of standard and custom colours. White is the most widely used, but we can accommodate custom colour requirements. Confirm your colour requirement at the enquiry stage and we will advise on available options.
What wind speed can your structures withstand?
Our structures are designed to withstand wind speeds of 200 km/h and above, subject to structural calculation. The actual design wind speed is determined by the project location’s wind zone classification. Every project receives a site-specific structural analysis.
Ready to Specify Your Project?