The successful delivery of a high-performance Tensile Structure relies on a rigorous engineering lifecycle. By integrating advanced Finite Element Analysis (FEA) with specialized Fabric engineering, we ensure every project maintains structural integrity under extreme conditions, including 150km/h wind loads and seismic variables.

Phase 01

Site Assessment & Environmental Load Calibration

Engineering begins with the precise definition of site-specific environmental parameters. Our structural engineers establish the core design criteria required to secure large-scale shading systems.

Wind Resistance: 120-150km/h
Load Analysis: ASCE 7 Standard
Seismic Category: Zone 3/4 Calibration
Phase 02

Computational Form-Finding & FEA Modeling

Unlike rigid buildings, a tensile system gains its stiffness from the pre-stress applied to the membrane. We utilize non-linear algorithms to determine the optimal "Form-Found" equilibrium of the structural membrane.

  • Geometric form-finding using Large Displacement Analysis.
  • Warp and Weft biaxial compensation calculations for 2D patterning.
  • Extraction of reaction forces for connection and foundation design.
Phase 03

Industrial Fabrication & Protective Coating

Components are manufactured in a controlled environment to ensure precision. We utilize high-strength Q345B steel sections, treated with professional-grade protective finishes to withstand atmospheric degradation.

Cấp thép: Q345B High-Tensile
Corrosion Protection: C3-Grade Epoxy/Zinc
Welding: High-Frequency (HF) Fusion

Membrane panels are joined using fusion technology, ensuring that seam tensile strength exceeds the base material rating of the architectural membrane.

Phase 04

Foundation Engineering & Uplift Management

Lightweight structures often generate significant uplift forces rather than just gravity loads. Foundations must be engineered with reinforced concrete footings and heavy-duty anchor bolt systems, cast to a tolerance of ±2mm.

Phase 05

Logistics & Structural Skeleton Erection

Modular steel components are transported to the site for assembly. The steel skeleton serves as the primary support for the fabric roofing system. During this phase, all connection nodes are inspected for smooth transitions to prevent membrane abrasion.

Phase 06

Hydraulic Tensioning & Commissioning

The final phase defines the longevity of the structure. Using hydraulic jacks and calibrated torque tools, we apply the design pre-stress across the membrane surface to achieve a perfect double-curvature form.

  • Biaxial tensioning to reach calculated equilibrium.
  • Torque verification of all mechanical fasteners.
  • Ultrasonic tension measurement of edge cables and tie-backs.

Cần một đề xuất kỹ thuật?

Gửi cho chúng tôi kích thước công trình của bạn và các kỹ sư của chúng tôi sẽ cung cấp bản thiết kế 3D và báo giá miễn phí.
Danh mục mẫu yêu cầu
Yêu cầu
Báo giá dự án

Chia sẻ yêu cầu về kiến trúc tensile của bạn với chúng tôi. Các chuyên gia kỹ thuật của chúng tôi sẽ xem xét dự án của bạn và cung cấp giải pháp sơ bộ phù hợp trong vòng 24 giờ.

Hãy cho chúng tôi biết về dự án của bạn

Biểu mẫu yêu cầu bật lên

100% Bảo mật & An toàn

×
Hỗ trợ
Đội Ngũ Hỗ Trợ
               

Xin chào! 👋 Chúng tôi có thể giúp gì cho bạn hôm nay?

WhatsApp
Gọi Cho Chúng Tôi Ngay
Hỗ Trợ Qua Email
WhatsApp Gọi Yêu Cầu Báo Giá Email